Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36616712

RESUMO

For many years there has been a strong research interest in soft electronics for artificial skin applications. However, one challenge with stretchable devices is the limited availability of high performance, stretchable, electrical conductors and semiconductors that remain stable under strain. Examples of such electronic skin require excessive amounts of wires to address each sensing element-compression force and strain-in a conventional matrix structure. Here, we present a new process for fabricating artificial skin consisting of an optical waveguide architecture, enabling wide ranging sensitivity to external mechanical compression and strain. The manufacturing process allows design of a fully stretchable polydimethylsiloxane elastomer waveguide with embedded gratings, replicated from low cost DVD-Rs. This optical artificial skin allows the detection of compression forces from 0 to 3.8 N with controllable sensitivity. It also permits monitoring of elongation deformations up to 135%. This type of stretchable optical sensor is highly robust, transparent, and presents a large sensing area while limiting the amount of wires connecting to the sensor. Thus, this optical artificial skin presents far superior mechanical properties compared to current electronic skin.


Assuntos
Dispositivos Eletrônicos Vestíveis , Elastômeros , Eletrônica , Fenômenos Mecânicos , Pressão
2.
Nanotechnology ; 32(30)2021 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-33789258

RESUMO

Replicating the functionality of the human eye has been a challenge for more than a century, creating a great wealth of biomimetic and bioinspired devices, and providing ever improving models of the eye for myriad research purposes. As improvements in microelectronics have proceeded, individual components of the eye have been replicated, and models of the optical behaviour of the eye have improved. This review explores both work developed for improving medical components, with an ultimate aim of a fully functioning prosthetic eye, and work looking at improving existing devices through biomimetic means. It is hoped that this holistic approach to the subject will aid in the cross pollination of ideas between the two research foci. The review starts by summarising the reported measurements of optical parameters of various components of the eye. It then charts the development of individual bionic components. Particular focus is put on the development of bionic and biomimetic forms of the two main adaptive components of the eye, namely the lens and the iris, and the challenges faced in modelling the light sensitive retina. Work on each of these components is thoroughly reviewed, including an overview of the principles behind the many different approaches used to mimic the functionality, and discussion of the pros and cons of each approach. This is concluded by an overview of several reported models of the complete or semi-complete eye, including details of the components used and a summary of the models' functionality. Finally, some consideration is given to the direction of travel of this field of research, and which existing approaches are likely to bring us closer to the long term goal of a fully functional analogue of the eye.


Assuntos
Biomimética , Olho , Próteses Visuais , Animais , Materiais Biomiméticos/química , Olho/anatomia & histologia , Humanos , Lentes Intraoculares , Fenômenos Fisiológicos Oculares
3.
Biomed Opt Express ; 11(8): 4548-4559, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32923063

RESUMO

Currently, many diseases of the eye are treated by laser surgery. An understanding of light propagation and the heating of eye tissue during laser exposure is crucial to improving the outcome of these procedures. Here, we present the development of physical and computational models of the human eye by combining optical light propagation and thermal characteristics. For the physical model, all parts of the eye, including cornea, lens, ciliary body, sclera, aqueous and vitreous humors, and iris, were fabricated using a 3D printed holder and modified polydimethylsiloxane. We also present a computational model based on finite element analysis that allows for a direct comparison between the simulation and experimental measurements. These models provide an opportunity to directly assess the rise in temperature in all eye tissues. The simulated and physical models showed good agreement for the transmission of light at varying incident angles. The heating of optical components was investigated in the retina and the ciliary body during simulated laser surgery. Temperature increases of 45.3°C and 30.6°C in the retina and ciliary bodies, respectively, were found in the physical model after 1 minute of exposure to 186 mW of 850 nm laser radiation. This compared to 29.8°C and 33.9°C increases seen under the same conditions in the simulation model with human eye parameters and 48.1°C and 28.7°C for physical model parameters. These results and these models are very promising for further investigation of the impact of laser surgery.

4.
Sensors (Basel) ; 20(3)2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-31979190

RESUMO

Development of stretchable electronics has been driven by key applications such as electronics skin for robotic or prosthetic. Mimicking skin functionalities imposes at a minimal level: stretchability, pressure, and temperature sensing capabilities. While the research on pressure sensors for artificial skin is extensive, stretchable temperature sensors remain less explored. In this work, a stretchable temperature and infrared sensor has been developed on a polydimethylsiloxane substrate. The sensor is based on poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE) as a pyroelectric material. This material is sandwiched between two electrodes. The first one consists of aluminium serpentines, covered by gold in order to get electrical contact and maximum stretchability. The second one is based on poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) that has shown good electrical compatibility with PVDF-TrFE and provides the stretchability of the top electrode. Without poling the PVDF-TrFE, sensor has shown a sensitivity of around 7 pF.°C-1 up to 35% strain without any change in its behaviour. Then, taking advantage on infrared absorption of PEDOT:PSS, a poled device has shown a pyroelectric peak of 13 mV to an infrared illumination of 5 mW at 830 nm. This stretchable device valuably allows an electronic skin (e-skin) use for contact and more importantly non-contact thermal sensing.


Assuntos
Técnicas Biossensoriais/métodos , Dispositivos Eletrônicos Vestíveis , Polivinil/química , Temperatura
5.
J Biophotonics ; 12(11): e201800398, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31251453

RESUMO

The eye is a very sophisticated system of optical elements for the preeminent sense of vision. In recent years, the number of laser surgery to correct the optical aberration such as myopia or astigmatism has significantly increased. Consequently, improving the knowledge related to the interactions of light with the eye is very important in order to enhance the efficiency of the surgery. For this reason, a complete optical characterization of the porcine eye is presented in this study. Kubelka-Munk and Inverse Adding-Doubling methods were applied to spectroscopy measurement to determine the absorption and scattering coefficients. Furthermore, the refractive index has been measured by ellipsometry. The different parameters were obtained for the cornea, lens, vitreous humor, sclera, iris, choroids and eyelid in the visible and infrared region. Thereafter, the results are implemented in a COMSOL Multiphysics® software to create an eye model. This model gives a better understanding of the propagation of light in the eye by adding optical parts such as the iris, the sclera or the ciliary bodies. Two simulations show the propagation of light from the cornea to the retina but also from the sclera to the retina. This last possibility provides a better understanding of light propagation during eye laser surgery such as, for example, transscleral cyclophotocoagulation. Figure: Eye simulation models allow the development of new laser treatments in a simple and safe way for patients. To this purpose, the creation of an eye simulated model based on optical parameters obtained from experimental data is presented in this study. This model will facilitate the understanding of the light propagation inside the porcine eye.


Assuntos
Olho , Modelos Biológicos , Fenômenos Ópticos , Absorção Fisico-Química , Animais , Olho/química , Refratometria , Suínos
6.
Sensors (Basel) ; 19(9)2019 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-31058810

RESUMO

In this paper, we demonstrate the first attempt of encapsulating a flexible micro battery into a contact lens to implement an eye-tracker. The paper discusses how to scale the battery to power various circuits embedded in the contact lens, such as ASIC, photodiodes, etc., as well as how to combine the battery with external harvested energy sources. The fabricated ring battery has a surface area of 0.75 cm2 yielding an areal capacity of 43 µAh·cm-2 at 20C. Based on simulated 0.35-µm CMOS ASIC power consumption, this value is large enough to allow powering the ASIC for 3 minutes. The functioning of the micro battery is demonstrated by powering an orange LED.


Assuntos
Técnicas Biossensoriais , Lentes de Contato , Fontes de Energia Elétrica , Movimentos Oculares/fisiologia , Humanos , Fenômenos Fisiológicos Oculares
7.
Adv Biosyst ; 3(3): e1800249, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-32627404

RESUMO

E-cigarettes have been suggested as a potentially healthier alternative to cigarettes based on studies using cell viability, DNA damage, and transcriptional response assays. However, little is known about the effect of e-cigarette aerosols on the integrity of the tracheal epithelium, specifically with respect to barrier resistance. This is partly due to the lack of methods for monitoring epithelia at the air-liquid interface (ALI), i.e., under physiological conditions. Here, it is shown that an organic electrochemical transistor can be adapted for the measurement of barrier resistance at the ALI. This technology enables accurate, continuous quantification of tracheal barrier integrity through the use of a conformable gate electrode placed on top of the cell-secreted mucus, obviating the need for addition of culture medium or buffer as a conductance medium for rigid electrodes. This platform allows for the detection of a dose-dependent, rapid decrease in barrier resistance of an in vitro model of human bronchial epithelium (MucilAir) after E-cigarette aerosols exposure. The system represents a powerful tool to study tissue responses of the human airway epithelium to inhaled smoke. The same technology will have broad applications for toxicology studies on other tissues with ALI, including other airway tissues and skin.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Modelos Biológicos , Poluição por Fumaça de Tabaco , Traqueia/citologia , Técnicas de Cultura de Células/instrumentação , Células Cultivadas , Técnicas Eletroquímicas/instrumentação , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade
8.
Sci Rep ; 8(1): 8477, 2018 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-29855553

RESUMO

We describe a process allowing the patterning of fully stretchable organic electrochemical transistors (OECTs). The device consists of an active stretchable area connected with stretchable metallic interconnections. The current literature does not provide a complete, simple and accurate process using the standard thin film microelectronic techniques allowing the creation of such sensors. An innovative patterning process based on the combination of laser ablation and thermal release tape ensures the fabrication of highly stretchable metallic lines - encapsulated in polydimethylsiloxane - from conventional aluminium tape. State-of-the-art stretchability up to 70% combined with ultra-low mOhms resistance is demonstrated. We present a photolithographic process to pattern the organic active area onto stretchable substrate. Finally the formulation of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) is tuned to achieve an OECT with a maximum stretchability of 38% while maintaining transconductance up to 0.35 mS and channel current as high as 0.2 mA.

9.
Environ Sci Pollut Res Int ; 24(1): 33-41, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26884239

RESUMO

Various water samples were successfully evaluated using a panel of different recombinant bioluminescent bacteria and estrogenic activity analysis. The bioluminescent bacteria strains induced by oxidative (superoxide radical or hydroxyl radical), protein damage, cell membrane damage, or cellular toxicity were used. Estrogenic activities were examined by using the yeast strain BY4741, which carries the ß-galactosidase reporter gene under the control of the estrogen-responsive element (ERE). A total of 14 samples from three wastewater treatment plants, one textile factory, and seawater locations in Tunisia were analyzed. A wide range of bio-responses were described. Site/sample heterogeneity was prevalent, in combination with generally high relative bioluminescence scores for oxidative stress (OH•). Estrogenic activity was detected at all sites and was particularly elevated at certain sites. Our perspectives include the future exploration of the variation detected in relation to treatment plant operations and environmental impacts. In conclusion, this new multi-experimental method can be used for rapid bio-response profile monitoring and the evaluation of environmental samples spanning a wide range of domains. This study confirms that bio-reactive wastewater treatment plant (WWTP) effluents are discharged into seawater, where they may impact coastal populations.


Assuntos
Bioensaio/métodos , Monitoramento Ambiental/métodos , Águas Residuárias/toxicidade , Poluentes Químicos da Água/toxicidade , Técnicas Biossensoriais , Disruptores Endócrinos/química , Disruptores Endócrinos/toxicidade , Estrogênios/análise , Estrona/análise , Resíduos Industriais , Água do Mar , Tunísia , Águas Residuárias/química , Poluentes Químicos da Água/química , Leveduras , beta-Galactosidase
10.
Microsyst Nanoeng ; 3: 17028, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31057869

RESUMO

Future drug discovery and toxicology testing could benefit significantly from more predictive and multi-parametric readouts from in vitro models. Despite the recent advances in the field of microfluidics, and more recently organ-on-a-chip technology, there is still a high demand for real-time monitoring systems that can be readily embedded with microfluidics. In addition, multi-parametric monitoring is essential to improve the predictive quality of the data used to inform clinical studies that follow. Here we present a microfluidic platform integrated with in-line electronic sensors based on the organic electrochemical transistor. Our goals are two-fold, first to generate a platform to host cells in a more physiologically relevant environment (using physiologically relevant fluid shear stress (FSS)) and second to show efficient integration of multiple different methods for assessing cell morphology, differentiation, and integrity. These include optical imaging, impedance monitoring, metabolite sensing, and a wound-healing assay. We illustrate the versatility of this multi-parametric monitoring in giving us increased confidence to validate the improved differentiation of cells toward a physiological profile under FSS, thus yielding more accurate data when used to assess the effect of drugs or toxins. Overall, this platform will enable high-content screening for in vitro drug discovery and toxicology testing and bridges the existing gap in the integration of in-line sensors in microfluidic devices.

11.
Sci Adv ; 1(4): e1400251, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26601178

RESUMO

Despite recent interest in organic electrochemical transistors (OECTs), sparked by their straightforward fabrication and high performance, the fundamental mechanism behind their operation remains largely unexplored. OECTs use an electrolyte in direct contact with a polymer channel as part of their device structure. Hence, they offer facile integration with biological milieux and are currently used as amplifying transducers for bioelectronics. Ion exchange between electrolyte and channel is believed to take place in OECTs, although the extent of this process and its impact on device characteristics are still unknown. We show that the uptake of ions from an electrolyte into a film of poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate ( PEDOT: PSS) leads to a purely volumetric capacitance of 39 F/cm(3). This results in a dependence of the transconductance on channel thickness, a new degree of freedom that we exploit to demonstrate high-quality recordings of human brain rhythms. Our results bring to the forefront a transistor class in which performance can be tuned independently of device footprint and provide guidelines for the design of materials that will lead to state-of-the-art transistor performance.

12.
Sci Rep ; 5: 11613, 2015 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-26112429

RESUMO

Impedance sensing of biological systems allows for monitoring of cell and tissue properties, including cell-substrate attachment, layer confluence, and the "tightness" of an epithelial tissue. These properties are critical for electrical detection of tissue health and viability in applications such as toxicological screening. Organic transistors based on conducting polymers offer a promising route to efficiently transduce ionic currents to attain high quality impedance spectra, but collection of complete impedance spectra can be time consuming (minutes). By applying uniform white noise at the gate of an organic electrochemical transistor (OECT), and measuring the resulting current noise, we are able to dynamically monitor the impedance and thus integrity of cultured epithelial monolayers. We show that noise sourcing can be used to track rapid monolayer disruption due to compounds which interfere with dynamic polymerization events crucial for maintaining cytoskeletal integrity, and to resolve sub-second alterations to the monolayer integrity.


Assuntos
Técnicas Eletroquímicas/métodos , Fenômenos Eletrofisiológicos/fisiologia , Polímeros/química , Transistores Eletrônicos , Animais , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Cães , Impedância Elétrica , Eletricidade , Técnicas Eletroquímicas/instrumentação , Eletrodos , Células Madin Darby de Rim Canino , Ruído , Reprodutibilidade dos Testes , Fatores de Tempo
13.
Chemphyschem ; 16(6): 1210-6, 2015 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-25752503

RESUMO

The organic electrochemical transistor (OECT) is a unique device that shows great promise for sensing in biomedical applications such as monitoring of the integrity of epithelial tissue. It is a label-free sensor that is amenable to low-cost production by roll-to-roll or other printing technologies. Herein, the optimization of a planar OECT for the characterization of barrier tissue is presented. Evaluation of surface coating, gate biocompatibility and performance, and optimization of the geometry of the transistor are highlighted. The conducting polymer poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate), which is used as the active material in the transistor, has the added advantage of allowing significant light transmission compared to traditional electrode materials and thus permits high-quality optical microscopy. The combination of optical and electronic monitoring of cells shown herein provides the opportunity to couple two very complementary techniques to yield a low-cost method for in vitro cell sensing.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Técnicas Eletroquímicas , Células Epiteliais/química , Polímeros/química , Poliestirenos/química , Animais , Compostos Bicíclicos Heterocíclicos com Pontes/metabolismo , Cães , Eletrodos , Células Epiteliais/metabolismo , Células Madin Darby de Rim Canino , Polímeros/metabolismo , Poliestirenos/metabolismo
14.
Adv Mater ; 26(44): 7450-5, 2014 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-25312252

RESUMO

An organic electrochemical transistor operates in accumulation mode with high transconductance. The channel comprises a thiophene-based conjugated polyelectrolyte, which is p-type doped by anions injected from a liquid electrolyte upon the application of a gate voltage. The use of ethylene glycol as a co-solvent dramatically improves the transconductance and the temporal response of the transistors.


Assuntos
Transistores Eletrônicos , Ânions/química , Desenho de Equipamento , Etilenoglicol/química , Microscopia de Força Atômica , Polímeros/química , Solventes/química , Análise Espectral , Tiofenos/química
15.
Adv Mater ; 26(41): 7083-90, 2014 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-25179835

RESUMO

A planar, conducting-polymer-based transistor for combined optical and electronic monitoring of live cells provides a unique platform for monitoring the health of cells in vitro. Monitoring of MDCK-I epithelial cells over several days is shown, along with a demonstration of the device for toxicology studies, of use in future drug discovery or diagnostics applications.


Assuntos
Equipamentos e Provisões Elétricas , Células Epiteliais/citologia , Dispositivos Ópticos , Poliestirenos/química , Tiofenos/química , Transistores Eletrônicos , Animais , Cães , Células Madin Darby de Rim Canino
16.
J Vis Exp ; (84): e51102, 2014 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-24561449

RESUMO

The gastrointestinal tract is an example of barrier tissue that provides a physical barrier against entry of pathogens and toxins, while allowing the passage of necessary ions and molecules. A breach in this barrier can be caused by a reduction in the extracellular calcium concentration. This reduction in calcium concentration causes a conformational change in proteins involved in the sealing of the barrier, leading to an increase of the paracellular flux. To mimic this effect the calcium chelator ethylene glycol-bis(beta-aminoethyl ether)-N,N,N',N'-tetra acetic acid (EGTA) was used on a monolayer of cells known to be representative of the gastrointestinal tract. Different methods to detect the disruption of the barrier tissue already exist, such as immunofluorescence and permeability assays. However, these methods are time-consuming and costly and not suited to dynamic or high-throughput measurements. Electronic methods for measuring barrier tissue integrity also exist for measurement of the transepithelial resistance (TER), however these are often costly and complex. The development of rapid, cheap, and sensitive methods is urgently needed as the integrity of barrier tissue is a key parameter in drug discovery and pathogen/toxin diagnostics. The organic electrochemical transistor (OECT) integrated with barrier tissue forming cells has been shown as a new device capable of dynamically monitoring barrier tissue integrity. The device is able to measure minute variations in ionic flux with unprecedented temporal resolution and sensitivity, in real time, as an indicator of barrier tissue integrity. This new method is based on a simple device that can be compatible with high throughput screening applications and fabricated at low cost.


Assuntos
Trato Gastrointestinal/química , Mucosa Intestinal/química , Junções Íntimas/química , Transistores Eletrônicos , Células CACO-2 , Ácido Egtázico/química , Ácido Egtázico/farmacologia , Trato Gastrointestinal/citologia , Trato Gastrointestinal/efeitos dos fármacos , Trato Gastrointestinal/metabolismo , Humanos , Mucosa Intestinal/citologia , Mucosa Intestinal/efeitos dos fármacos , Mucosa Intestinal/metabolismo , Junções Íntimas/efeitos dos fármacos , Junções Íntimas/metabolismo
17.
Adv Healthc Mater ; 3(7): 1053-60, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24497469

RESUMO

Ion flow across polarized epithelia is a tightly regulated process. Measurement of the transepithelial resistance is a highly relevant parameter for assessing the function or health of the tissue. Dynamic, electrical measurements of transepithelial ion flow are preferred as they provide the most accurate snapshot of effects of external stimuli. Enteric pathogens such as Salmonella typhimurium are known to disrupt ion flow in gastrointestinal epithelia. Here, for the first time, the use of organic transistors as a powerful potential alternative for front-line, disposable, high-throughput diagnostics of enteric pathogens is demonstrated. The transistors' ability to detect early and subtle changes in transepithelial ion flow is capitalized upon to develop a highly sensitive detector of epithelial integrity. Stable operation of the organic devices under physiological conditions is shown, followed by dynamic, pathogen-specific diagnosis of infection of epithelia. Further, operation of the device is possible in complex matrices, showing particular promise for food and safety applications.


Assuntos
Técnicas Eletroquímicas/métodos , Epitélio/microbiologia , Interações Hospedeiro-Patógeno/fisiologia , Infecções por Salmonella/fisiopatologia , Salmonella typhimurium/fisiologia , Animais , Células CACO-2 , Técnicas Eletroquímicas/instrumentação , Eletrodos , Desenho de Equipamento , Humanos , Cinética , Leite/microbiologia
18.
J Mater Chem B ; 1(31): 3860-3867, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32261140

RESUMO

Conducting polymers (CPs) are increasingly being used to interface with cells for applications in both bioelectronics and tissue engineering. To facilitate this interaction, cells need to adhere and grow on the CP surface. Extracellular matrix components are usually necessary to support or enhance cell attachment and growth on polymer substrates. Here we show the preparation of PEDOT(TOS):gelatin composites as a new biocompatible substrate for use in tissue engineering. Gelatin, a derivative of the extracellular matrix protein collagen, was incorporated into poly(3,4 ethylenedioxythiophene)-tosylate (PEDOT(TOS)) films via vapour phase polymerisation (VPP) without changing the electrochemical properties of the CP. Further, gelatin, incorporated into the PEDOT(TOS) film, was found to specifically support bovine brain capillary endothelial cell adhesion and growth, indicating that the functionality of the biomolecule was maintained. The biocompatibility of the composite films was demonstrated indicating the significant future potential of biocomposites of this type for use in promoting cell adhesion in electrically active materials for tissue engineering.

19.
ACS Nano ; 6(11): 10384-95, 2012 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-23113673

RESUMO

Carbon allotropes possess unique and interesting physical, chemical, and electronic properties that make them attractive for next-generation electronic devices and solar cells. In this report, we describe our efforts into the fabrication of the first reported all-carbon solar cell in which all components (the anode, active layer, and cathode) are carbon based. First, we evaluate the active layer, on standard electrodes, which is composed of a bilayer of polymer sorted semiconducting single-walled carbon nanotubes and C(60). This carbon-based active layer with a standard indium tin oxide anode and metallic cathode has a maximum power conversion efficiency of 0.46% under AM1.5 Sun illumination. Next, we describe our efforts in replacing the electrodes with carbon-based electrodes, to demonstrate the first all-carbon solar cell, and discuss the remaining challenges associated with this process.


Assuntos
Fontes de Energia Elétrica , Eletrodos , Nanotecnologia/instrumentação , Nanotubos de Carbono/química , Energia Solar , Desenho de Equipamento , Análise de Falha de Equipamento , Conformação Molecular
20.
Adv Mater ; 24(24): 3223-7, 2012 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-22641411

RESUMO

Optical pressure sensors are highly responsive and are unaffected by surrounding parameters such as electronic noise, humidity, temperature, etc. A new type of optical pressure sensor is described that demonstrates the stretchability and transparency of a polydimethylsiloxane waveguide, while also serving as a substrate. The pressure sensors are both robust and easy to fabricate over a large area.


Assuntos
Biomimética , Equipamentos e Provisões Elétricas , Fenômenos Ópticos , Pressão , Dimetilpolisiloxanos/química , Luz , Semicondutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...